Spec lookup by model number

The RLA/LRA numbers that decide breaker sizing, fuse selection and backup-power feasibility — extracted from manufacturer spec sheets, each with its source link. Built for HVAC techs, electricians and anyone sizing power for a specific unit.

Zoeller (15)

ModelTypeVoltsHPElectrical
M53 sump pump (Mighty-Mate cast-iron sump, auto) 115/1 3/10 FLA 9.7A details →
M55 sump pump (Bronze sump, auto) 115/1 3/10 FLA 9.7A details →
N53 sump pump (Non-automatic sump) 115/1 3/10 FLA 9.7A details →
BN53 sump pump (Bronze, piggyback switch) 115/1 3/10 FLA 9.7A details →
BE53 sump pump (230V non-automatic) 230/1 3/10 FLA 4.8A details →
D53 sump pump (230V duplex-ready auto) 230/1 3/10 FLA 4.8A details →
E53 sump pump (230V non-automatic) 230/1 3/10 FLA 4.8A details →
M57 sump pump (All cast-iron sump, auto) 115/1 3/10 FLA 9.7A details →
M59 sump pump (All bronze sump, auto) 115/1 3/10 FLA 9.7A details →
N57 sump pump (Non-automatic cast iron) 115/1 3/10 FLA 9.7A details →
D57 sump pump (230V auto cast iron) 230/1 3/10 FLA 4.8A details →
E57 sump pump (230V non-automatic cast iron) 230/1 3/10 FLA 4.8A details →
E59 sump pump (230V non-automatic bronze) 230/1 3/10 FLA 4.8A details →
M98 sump pump (high-capacity sump) 115/1 1/2 FLA 9.4A details →
M267 sewage ejector (2in solids sewage pump) 115/1 1/2 FLA 9.4A details →

Goodman (13)

ModelTypeVoltsHPElectrical
GSX140181L AC condenser (18000) 208/230/1 — RLA 6A · LRA 37.5A · fan FLA 0.7A details →
GSX140181M AC condenser (18000) 208/230/1 — RLA 6A · LRA 37.5A · fan FLA 0.65A details →
GSX140191K AC condenser (18000) 208/230/1 — RLA 9A · LRA 47.5A · fan FLA 0.7A details →
GSX140241L AC condenser (24000) 208/230/1 — RLA 7.7A · LRA 38A · fan FLA 0.7A details →
GSX140251L AC condenser (24000) 208/230/1 — RLA 13.5A · LRA 58.3A · fan FLA 0.7A details →
GSX140301K AC condenser (30000) 208/230/1 — RLA 12.8A · LRA 64A · fan FLA 0.95A details →
GSX140311K AC condenser (30000) 208/230/1 — RLA 12.8A · LRA 67.8A · fan FLA 0.95A details →
GSX140361K AC condenser (36000) 208/230/1 — RLA 14.1A · LRA 77A · fan FLA 0.95A details →
GSX140371K AC condenser (36000) 208/230/1 — RLA 14.1A · LRA 72.2A · fan FLA 0.95A details →
GSX140421K AC condenser (42000) 208/230/1 — RLA 16.7A · LRA 79A · fan FLA 0.95A details →
GSX140431K AC condenser (42000) 208/230/1 — RLA 16.7A · LRA 79A · fan FLA 0.95A details →
GSX140481K AC condenser (48000) 208/230/1 — RLA 19.9A · LRA 109A · fan FLA 1.3A details →
GSX140601K AC condenser (60000) 208/230/1 — RLA 25A · LRA 134A · fan FLA 1.3A details →

Franklin Electric (7)

ModelTypeVoltsHPElectrical
1/2HP 2-wire submersible well pump motor (max load 6.0A; 4in 3450RPM encapsulated) 230/1 1/2 FLA 5A · LRA 32.2A details →
3/4HP 2-wire submersible well pump motor (max load 8.0A; 4in 3450RPM encapsulated) 230/1 3/4 FLA 6.8A · LRA 40.7A details →
1HP 2-wire submersible well pump motor (max load 10.4A; 4in 3450RPM encapsulated) 230/1 1 FLA 8.2A · LRA 48.7A details →
1.5HP 2-wire submersible well pump motor (max load 13.1A; 4in 3450RPM encapsulated) 230/1 1.5 FLA 10.6A · LRA 66.2A details →
1/2HP 3-wire submersible well pump motor (max load 6.0A; 4in 3450RPM encapsulated) 230/1 1/2 FLA 5A · LRA 23A details →
3/4HP 3-wire submersible well pump motor (max load 8.0A; 4in 3450RPM encapsulated) 230/1 3/4 FLA 6.8A · LRA 34.2A details →
1HP 3-wire submersible well pump motor (max load 10.4A; 4in 3450RPM encapsulated) 230/1 1 FLA 8.2A · LRA 41.8A details →

Dometic (2)

ModelTypeVoltsHPElectrical
457915.70X RV rooftop AC (white variant) 115/1 — RLA 12.4A · LRA 63A · fan FLA 2.5A details →
B57915.71X RV rooftop AC (current SKU) 115/1 — RLA 12.4A · LRA 68A · fan FLA 2.5A details →