Methodology

Two things decide whether a recommendation is honest: the data underneath it and what the math does with that data. Both are public here.

1 · The appliance library

130 appliance rows, 130 of them verified against their cited source, drawn from 61 distinct sources:

Source layerRowsWhat it means
Manufacturer specifications46Spec sheets, install manuals, technical data (Goodman, Zoeller, Franklin, Dometic, ResMed, Starlink…)
ENERGY STAR certified data36Aggregated from the official ENERGY STAR product APIs — every stat re-computable from the public dataset
U.S. DOE-derived table19The Virginia Tech Extension reproduction of the DOE appliance table
Cross-checked class values29Device-class values confirmed against ≥2 independent sources; labeled as class estimates, not single-model nameplates

A row counts as verified only when its value reproduces from the cited source (API re-query, PDF text extraction, or page comparison), with the evidence and date recorded. Aggregates from ENERGY STAR are re-checked automatically every week against the live datasets, so certified values can't silently rot.

2 · The sizing engine

The engine is deterministic and runs the same at build time (static answers) and in your browser (interactive calculator):

  1. Running watts — sum of every selected device's continuous draw. This sets the minimum inverter rating (plus 10% headroom).
  2. Startup surge — the single highest inrush moment: motors don't start at running power. We publish per-device surge values — from official Locked-Rotor Amps (LRA) where manufacturers list them (e.g. a ½HP submersible well pump: 32.2A LRA × 230V ≈ 7,400W), from the physics of small compressor motors (conventional fridge compressors start at roughly 9–12× running power), or the generic 3× motor rule where nothing better is published. Inverter-driven compressors are the exception — they ramp and have no locked-rotor spike, and we say so.
  3. Daily energy (Wh) — each device's watts × its duty cycle (DOE / ENERGY STAR usage hours), summed.
  4. Recommended capacity — daily Wh × 1.25, covering inverter conversion losses and usable depth of discharge. Your selection of backup duration (4/12/24/72h) scales this.